General Introduction

Tokyo Keiso M-900 variable area flowmeter comes with main characters as bel

1.1 Compact design

Small and light design offers easy installation onto panels as well as process pipings.

1.2 High sensitivity

The pivot bearing and light weight pointer enable to follow float movement swiftly.

1.3 Suitable for corrosive and opaque fluids

Anti-corrosive materials such as titanium and MA276 are available to meet your specifications.

1.4 Easy reading of scale and pointer

The long pointer and wide linearized scale plate make your reading easier.

1.5 Supporting devices

Various supporting devices to meet your requirements are available such as flow control needle valve, strainer and constant flow valve

2. Short Specifications

Model

AM7000

Measuring fluid

Liquids, gases

Flow range

Liquids: Water (density 1.0g/cm³, viscosity   1.0mPa·s)

Min. 0 to 2 L/h

Max. 0 to 600 L/h

Gases: Air (0°C, 1atm)

Min. 0 to 60 L/h(nor)

Max. 0 to 17000 L/h(nor)

Fluid   temperature

Std.: 0 to 149°C

Option: -20 to -1°C (low temperature   type)

150 to 200°C (high   temperature type)

Fluid pressure

Std. up to 10MPa

Opt. up to 20MPa

(Subject to flange rating for flange   connection version)

Material

Body: SUS304

Tapered tube: SUS304

Float: SUS304

(Options: SUS316, SUS316L, MA276 (equiv.   to Hastelloy C), Titanium)

Process   connection

Standard type: Rc 3/8 Thread (On request   Rc1/4, 1/2 or 10,15,20,25mm flange)

Large flow type: Rc 1/2 Thread (On   request Rc3/8, 3/4 or 15,20,25mm flange)

Indication   accuracy

±1.5%F.S. as   standard.  ±1.0%F.S. available on request.

Additional   functions
  /Enclosure

M-90□: Local   indication / IP54 equivalent

M-91□: Local   indication + Pneumatic transmission / IP54 equivalent

M-95□: Local   indication + Alarm output with reed switch / IP54 equivalent

IS-M-95□: Local indication   + Alarm output with reed switch / Intrinsically safe

M-96□: Local   indication + Alarm output with photo electric switch / IP54 equivalent

Indication   accuracy

Standard type: ±3%F.S.(High   accuracy type ±2%F.S.)

Small flow type: ±5%F.S. for measurement   less than 10L/h or 300L/h(nor) for gas measurement
  (High accuracy type±3%F.S.)

Range ability

10 : 1 (10 : 2 for small ranges)